Endress+Hauser is working on a fix for the embedded WIBU Systems CodeMeter that have several critical and high rated vulnerabilities in multiple products, according to a report with CERT@VDE.

Sharon Brizinov and Tal Keren of Claroty reported these vulnerabilities to WIBU Systems.

The vulnerabilities affect:

  • SupplyCare Enterprise versions 3.0 to 3.3 with order codes of SCE30B, SCE31B, and SCE32B
  • DeviceCare versions From 1.02 up to 1.07 (current release) with order code of SFE 100
  • FieldCare version 2.15.00 with order code of SFE 500
  • FieldXpert versions from 1.03 up to 1.05 (current release) with order codes of SMT70, and SMT77
  • Field Data Manager versions 1.4.0 up to 1.5.1 (current release) with order codes of MS20, and MS21
  • OPC UA Connectivity Server version 1.2.0 with order code of 71350102

In one issue there is an improper input validation (CVE-2020-14513) where CodeMeter and the software using it may crash while processing a specifically crafted license update file due to unverified length fields. The CVSS v3.1 base score is 7.5.

Schneider Bold

In addition, there is a origin validation error (CVE-2020-14519) which allows an attacker to use the CodeMeter Runtime WebSockets API via a specifically crafted Java Script payload, which may allow alteration or creation of license files for CmActLicense using CmActLicense Firm Code when combined with CVE-2020-14515. The CVSS v3.1 base score is 8.1.

Also, there is a buffer access with incorrect length value (CVE-2020-14509) where multiple memory corruption vulnerabilities exist where the packet parser mechanism of CodeMeter does not verify length fields. An attacker could send specially crafted packets to exploit these vulnerabilities. The CVSS v3.1 base score is 10.0.

In another issue, there is an inadequate encryption strength (CVE-2020-14517) issue where protocol encryption can easily end up broken and the server accepts external connections, which may allow an attacker to remotely communicate with the Code Meter API. The CVSS v3.1 base score is 9.4.

In addition, there is an improper resource shutdown or release (CVE-2020-16233) issue where an attacker could send a specially crafted packet that could have the server send back packets containing data from the heap. The CVSS v3.1 base score is 7.5.

Also, there is an improper verification of cryptographic signature (CVE-2020-14515) where an attacker could modify existing license update files and even build one themselves. The CVSS v3.1 base score is 7.4.

For more Information, click here for the WIBU Advisories.

Most vulnerabilities have already been fixed in the current Code Meter versions 7.10. Use of this version requires additional mitigation measures to fix all CVEs.

WIBU SYSTEMS released a new Code Meter Runtime version 7.10a dated on 16.9.2020. All the known vulnerabilities are fixed with this version. Click here for the new version.