There is an ongoing threat from Iranian-affiliated advanced persistent threat (APT) actors targeting Internet-connected operational technology (OT) devices, and federal security agencies issued an advisory.

The devices include programmable logic controllers (PLCs) manufactured by Rockwell Automation/Allen-Bradley, Schneider Electric, Siemens, and potentially other brands/manufacturers.

These attacks resulted in operational disruptions and financial losses across multiple U.S. critical infrastructure sectors, including government services and facilities, water and wastewater systems, and energy, according to an updated report from the Cybersecurity and Infrastructure Security Agency (CISA).

This is an updated advisory, entitled “Iranian-Affiliated Cyber Actors Exploit Programmable Logic Controllers Across U.S. Critical Infrastructure” from one issued this past April. Additionally, the Federal Bureau of Investigation (FBI), National Security Agency (NSA), Environmental Protection Agency (EPA), Department of Energy (DoE), United States Cyber Command – Cyber National Mission Force (CNMF), and Department of the Treasury all contributed to the report.

What’s New in This Update:

Schneider Bold
  • Expanded Targeting: The advisory now includes observed targeting of Schneider Electric and Siemens PLCs, in addition to Rockwell Automation/Allen-Bradley and potentially other branded/manufacturer devices.
  • Updated Technical Details: New information on threat actor tactics, including use of configuration software to exfiltrate device project files, and expanded details on targeted ports and device models.
  • Enhanced Mitigations: Additional recommendations for securing cellular modems, implementing isolated architectures, validating project files, and detecting malicious changes in reusable code modules (such as Add-On Instructions/AOIs).
  • New Indicators of Compromise (IOCs): Updated tables of Internet Protocol (IP) addresses and timeframes associated with Iranian-affiliated APT activity.
Tactics Changing

Moreover, Iranian-affiliated APT actors continue to adapt their tactics, targeting a wider range of devices and sectors.

Key actions for users to take include:

  • Install PLCs consistent with manufacturers’ guidelines and security best practices.
  • Remove PLCs from direct internet exposure via secure gateway and firewall; work with IT/OT team members and/or integrators to perform this action.
  • Query available logs for the provided indicators of compromise (IoCs) and check available logs for suspicious traffic on the ports associated with OT devices, including 44818, 2222, 102, and 502, especially traffic originating from foreign hosting providers.
  • For Rockwell Automation devices, place the physical mode switch on the controller into run position.

Meanwhile, if you suspect your organization was a target of an attack, including against other branded PLC devices, contact the authoring agencies and PLC manufacturer for guidance.

Click here for more on the advisory.