Terracon Consultants of Olathe, Kansas, will conduct a teleconference with federal officials to discuss five apparent violations identified by the Nuclear Regulatory Commission (NRC) during an inspection.
The intent of the conference is to discuss the apparent violations identified in an April 1 inspection report. They include the loss a portable nuclear gauge from a company truck, which was later recovered by a member of the public; failure to properly control radioactive material, and the failure to make timely notifications to the NRC following the loss.
No decision on the final safety significance of the apparent violations or any NRC actions will be made at the meeting.
The NRC said in a letter the notice is for an inspection conducted on December 18 at the facility in Rocky Hill, Connecticut. The inspection was in response to a notification a portable nuclear gauge had been lost and recovered following the conduct of licensed activities on November 25, 2019, in Killingly, Connecticut.
The inspection consisted of an examination of selected procedures and representative records and interviews with personnel both directly and indirectly involved in the event.
Based on the results of this inspection, five apparent violations were identified and are being considered for escalated enforcement action, the NRC said.
The apparent violations involved Terracon Consultants’ failure to:
1. Control and maintain constant surveillance of licensed material in a controlled or unrestricted area that was not in storage, and to provide two independent physical controls whenever a portable gauge is not under the control and constant surveillance of the licensee
2. Provide a notification to the NRC immediately after the discovery of any lost, stolen, or missing licensed material.
3. Block and brace licensed material from movement incident to normal transportation
4. Lock the gauge’s handle of the source rod or placement of the gauge inside of a locked container to prevent unauthorized or accidental removal of the source rod from its shielded position
5. Follow Terracon Operating and Emergency procedures associated with the license, specifically the requirement for the gauge user to use a U.S. Department of Transportation Type A container when transporting the gauge.
NRC said it considers these apparent violations significant because the it entrusts licensees with the control of radioactive material. Terracon lost control of radioactive material which entered into the public domain, and as a result, radioactive material was lost in a manner that had a substantial potential to cause damage to the radioactive source and cause radiation exposures to members of the public in excess of NRC regulatory limits.
The teleconference will begin Wednesday at 9 a.m., Central Time, and will be open to the public. NRC officials will be available to answer questions from the public following the business portion of the meeting. The public will have the opportunity to listen to the meeting and ask questions via a phone bridge by calling 800-988-9484, passcode 2401745#.