Palisades Energy (Holtec) requested permission to use custom equipment and procedures to move a tilted nuclear fuel assembly from the reactor core to the spent fuel pool.

NRC is reviewing the September 30 request and has provided an opportunity for public comment. The NRC verified the fuel rods in the tilted assembly remain intact and safe while the review continues.

Palisades Nuclear Plant (PNP) in Covert, Michigan, entered Mode 6 (Refueling) and began loading fuel into the reactor vessel on August 30, according to the NRC public notice.

During core reload, fuel assembly DD41 ended up placed into core location H-1 and tilted over after being released by the refueling machine. DD41 currently is at a 30-degree angle with the lower tie plate in core location H-1 and the upper tie plate leaning against the core shroud on the opposite side of the core, according to the NRC public notice.

Schneider Bold

The proposed Updated Final Safety Analysis Report (UFSAR) changes would be effective for the duration of the recovery of the DD41 fuel assembly. That would include retrieving it from its current orientation in the reactor vessel, packaging it within an engineered transport canister, transporting the canister from the containment building to the spent fuel handling building, and placing of the canister and fuel assembly into the case loading area within the spent fuel pool.

No Significant Hazard

NRC staff reviewed the licensee’s proposed no significant hazards consideration determination. To that end, NRC staff is providing notice of its proposed determination of whether there is a significant hazards consideration.

Operation of PNP in accordance with the proposed amendment will not involve a significant increase in the probability or consequences of an accident previously evaluated.

Although the DD41 proposed fuel assembly restoration path differs from routine fuel handling practices due to the development of the Fuel Transfer Canister (FTC) and lifting system, the licensee evaluated the use of the Fuel Movement Device (FMD) and the FTC and determined the fuel handling methods and administrative controls provide equivalent protection to the routine methods. There is no significant increase in the probability of an accident.

Additionally, the licensee evaluated the potential dose consequences of an accident during DD41 recovery and found there is no significant increase in the consequences of an accident as compared to existing safety analyses.

The proposed amendment would modify the PNP licensing basis to allow for a one-time use fuel handling activity for recovery of DD41.

The proposed changes do not create the possibility of a new or different kind of accident from any previously evaluated, according to the NRC public notice.

The pressurized-water reactor located in Covert, MI, ceased operations in May 2022. In late 2023, Holtec began filing licensing and regulatory requests to the NRC to return the plant to operational status.

Holtec officials are eying a late 2026 return to service.

Click here to view Holtec’s permission request.