Acuren Inspection, Inc., is facing a $16,000 fine for violations of Nuclear Regulatory Commission (NRC) requirements involving the failure to prevent the entry of unauthorized individuals into a radiologically restricted area while radioactive material was in use.

An inspector identified three apparent violations associated with an incident that occurred during radiographic operations at a temporary jobsite near Bay City, Michigan, on June 11, 2021. During this radiographic operation, an employee of the licensee’s client bypassed the cones and signs the licensee had erected at the restricted area boundary and got within the high radiation area before a member of the radiography crew noticed the individual in the restricted area.

After reviewing the company’s response to the proposed violations, the NRC concluded Acuren, based in Duluth, Minnesota, failed to meet NRC requirements while performing radiography at a temporary job site near Bay City, Michigan.

As immediate corrective action upon identifying the member of the public in the high radiation area, the radiographer’s assistant yelled to the member of the public to exit the restricted area, which the person did.

The licensee then performed a safety stand down and recalled the crew back to the Portage, Michigan, office for safety retraining, removed from the project the radiographer who was sitting in the cab of the truck, and erected yellow and magenta ropes as additional barriers along the restricted area boundary when radiography resumed at this jobsite.

Schneider Bold

The NRC violations include:

  • Failure to ensure the radiographer was accompanied by at least one other qualified individual while performing radiography
  • Failure to maintain continuous direct visual surveillance of the radiographic operation to protect against the entry of unauthorized individuals into the high radiation area where radiography was performed
  • Failure to ensure radiography conducted at a temporary job site near Bay City, Michigan, a location other than a permanent radiographic installation, was conducted with a radiographer accompanied by at least one other qualified individual

The company has 60 days to dispute the fine or request involvement of a neutral third-party mediator to resolve the issues.