In those cases, you will want an instrument that will measure all your rectifier signals and digitize them to be transmitted back to the SCADA.
That is where Moore Industries comes in with its Cathodic Protection Monitoring System (CPMS).
The typical signals off a rectifier are DC output voltage 0-100V, DC current through a metering shunt. It produces0-100mV, structure to reference voltage -5V to 0 to +5V and you may have a 4-20mA signal representing rectifier temperature. Rectifiers commonly have redundant AC feeds. That means you will want to monitor the circuit breakers for each in the form of a discrete input.
Moore Industries’ CPMS can end up configured to monitor one or two rectifiers. Once the rectifier signals end up measured, they can store in MODBUS registers. A user can then read the signals either using serial MODBUS RTU or Ethernet MODBUS/TCP.
The CPMS Cathodic Protection Monitoring System monitors above and below ground impressed current cathodic protection systems to ensure proper corrosion protection is in place and operating at the right levels.
GPS can add in so it is possible to turn off banks of rectifiers to better measure pipeline voltages.

Cathodic Protection Monitoring System from Moore Industries will help ensure the anti-corrosion barrier stays active, reliable, and compliant with safety regulations.
Source: Moore Industries
Key CPMS attributes:
- Simultaneous dual MODBUS RTU and Ethernet communications
- Quick and simple programming using a web browser
- GPS Time feature provides an optional method for keeping accurate time
Click here to view the CPMS in the Moore Industries’ catalog.