A near miss incident occurred during riser handling operations on a rig in the Gulf of Mexico when personnel were pulling a slick riser joint and lowering it toward the riser skate when a thermoplastic riser fin detached and fell approximately 70 feet, striking the spider platform on the drill floor.

The crew stopped riser movement and conducted an immediate safety assessment, according to a report with the Bureau of Safety and Environmental Enforcement (BSEE). During the assessment, the crew found the impact had displaced the hole cover.

As a result, a drill crew member re-entered the area and repositioned the hole cover to restore open hole protection.

After the worker secured the hole cover and the drill floor ended up cleared, riser-handling operations resumed. However, as the driller continued to lower the slick joint to the riser skate, a second thermoplastic riser fin detached and fell onto the riser skate.

No personnel were in the drop zone during either event; however, crew members had been in the area less than one minute before the second fin detached.

Schneider Bold

Each fin weighed approximately 61 pounds, and each fall involved an estimated 4,276 foot pounds, or 5,798 joules, of kinetic energy. This amount of force could have caused a fatal injury if personnel had been in the impact area.

Investigation Findings

After conducting an investigation, BSEE found:

  • The fin retention system did not end up tensioned to Original Equipment Manufacturer, or OEM, specifications, and required torque verification steps not completed or documented before use.
  • Post-installation verification, including the required 48-hour re-torque, did not end up performed, leaving the retention system vulnerable during riser handling operations.
  • Refurbishment work performed during condition-based maintenance did not meet Original Equipment Manufacturer requirements. Deficiencies did not end up clearly communicated or detected during acceptance checks.
  • The legacy single-bolt tensioner system remained in service despite previous recommendations to replace it with an upgraded design.
  • Riser Fin near miss

    Resting spot of one fallen fin on left, while the impact location after striking the spider platform on drill floor on right.
    Source: BSEE

  • Entering the red zone to reposition the displaced hole cover immediately after the first dropped fin momentarily exposed personnel to a second dropped-object hazard.
  • Checklist use and adherence to procedures were inconsistent. Missing documentation, including unsigned or incomplete verification checklists, meant workers could not confirm critical installation steps.
  • Previous dropped-fin events in 2016, 2020, and 2025 occurred across multiple rigs, indicating a recurring industrywide vulnerability.
Recommendations

To help prevent similar incidents in the future, BSEE recommends that operators and contractors do the following:

  • Verify and document torque values for all riser-fin securing systems according to Original Equipment Manufacturer specifications, and ensure all required verification steps, including the 48-hour post-installation re-torque, end up completed before deployment or handling.
  • Implement manufacturer-recommended design improvements when performance concerns or upgrade advisories issued.
  • Reinforce procedural discipline by consistently applying established work practices and verification requirements.
  • Strengthen vendor quality assurance and acceptance controls to ensure refurbishment and maintenance activities meet Original Equipment Manufacturer requirements before equipment ends up accepted and placed into service.
  • Integrate dropped object risk assessments into riser-handling operations and verify all attached components end up properly installed and secured before lifting, lowering, or transferring equipment.
  • Review previous dropped-fin events across all rigs and apply lessons learned to strengthen fleetwide procedures and vendor oversight.

Pin It on Pinterest

Share This