An incident occurred at an offshore rig in the Gulf of Mexico where a worker sustained second-degree burns during a Fast Rescue Craft (FRC) training exercise.

During the exercise, a participant mistakenly activated a parachute flare instead of a handheld flare, according to a report from the Marine Minerals Administration, formerly the Bureau of Safety and Environmental Enforcement, (MMA). The parachute flare ended up aimed toward individual when it went off, resulting in burn injuries. The parachute flare was being used during the drill as part of an offshore expending activity.

In the report, MMA found several factors contributed to the incident, such as an inadequate hazard identification. It turns out the pre-job planning focused on fast rescue craft operations and did not fully address the hazards associated with handling, selecting and activating pyrotechnic devices.

Also, there was an inadequate risk assessment. The activity did not include a formal, task-specific risk assessment for offshore flare deployment or expending pyrotechnics.

Additionally, there was improper storage or segregation as different types of pyrotechnic devices ended up mixed together, which increased the likelihood of selecting the wrong device.

Schneider Bold

As in quite a few incidents there was a failure to follow procedures. It turns out, procedures and instructions were available but did not end up followed before and during the exercise.

Moreover, there was insufficient training or experience. The injured individual had limited experience with the task and did not receive required pre-task training before participating.

Recommendations

To help prevent similar incidents, the MMA recommends operators and contractors consider the following:

  • Due to onshore disposal requirements, identify methods or processes to eliminate offshore expending of pyrotechnics.
    Seek alternatives to pyrotechnics at fixed facilities that offer enhanced safety to personnel without the reduction in life safety equipment requirements such as already available installed alternatives such as VHF radios; emergency position-indicating radio beacons, or EPIRBs; search and rescue transponders, or SARTS
  • Evaluate the utility of pyrotechnic devices given floating offshore facilities are in well-known locations that are quickly and readily accessible to rescue resources.
  • Parachute flare

    Worker suffered burn injuries after a parachute flare struck the individual during a training exercise.
    Source: MMA

  • Determine if high-intensity, short-duration homing capability of a traditional pyrotechnic device are redundant when compared to the persistent signaling and precision of modern digital systems like emergency position-indicating radio beacons, or EPIRBs; search and rescue transponders, or SARTS; automatic identification system, or AIS; and VHF radios with digital selective calling, or VHF-DSCs; that are already on these facilities.
  • Strengthen risk assessment and task-specific controls during emergency drills for all steps involved in performing a specific task.
  • Ensure proper labeling exists on any flares to limit the likelihood of an individual firing in the wrong direction.
  • Ensure instruction(s) and procedure(s) are clear and acknowledged by all participants before starting an exercise or drill.
  • At offshore locations, improve training, procedural adherence, and pyrotechnic segregation practices.

Pin It on Pinterest