By Gregory Hale
Details on the fatal explosion and fire that broke out in the OPC Polymers unit at the Yenkin-Majestic Paint facility in Columbus, Ohio, last Thursday continue to trickle in, but the cause for now remains unknown as investigators got an overview of the resin manufacturing process.
One worker died and nine others suffered injuries in the early morning blast at the paint manufacturing plant.
A review of security video allowed the investigation team to develop a more precise time of the incident, according to a Tuesday update by the Chemical Safety and Hazard Investigation Board (CSB).
In an initial update of the explosion and fire that broke out in the OPC Polymers unit, the CSB said 21 employees were in the facility at the time of the incident and the blast resulted in substantial property damage of more than $1 million. In addition, a building in the OPC Polymer unit collapsed as a result of the incident.
Yenkin-Majestic provided investigators an overview of the resin manufacturing process, which is called alkyd resin manufacturing utilizing the company’s own technology.
In the process, materials mix in a metallic kettle which contains an agitator and ends up heated by a furnace before it goes to a scale tank and then to product storage. There are six kettles: Four are heated by gas furnaces and two are steam heated. The incident occurred during the batch production in Kettle #3.
Kettle #3 has a rated capacity of 20,900 lbs. and is heated by a gas furnace.
After the explosion and ensuing blaze, the fire suppression system in a portion of the paint production facility activated. Investigators verified there was no fire in the adjacent paint production facility, according to the CSB.
The east wall of the paint production facility sustained damaged as a result of the explosion in the adjacent OPC Resin facility.

A fire raged out of control after an explosion at the Yenkin-Majestic Paint facility in Columbus, Ohio, April 8. Investigators continue to sort out the details of the blast which originated during a batch process in Kettle #3 in the OPC Polymers unit.
Source: WBNS TV10 screencapture
Along those lines, Yenkin-Majestic hired a structural engineer to assess the structural integrity of the OPC Resin facility. In addition, the company this week is looking to remove the catch tank on top of the damaged OPC Resin building. The catch tank is part of a safety and environmental system used to contain unplanned discharges from a processing vessel.
At 12:05 a.m., fire officials got the call of an explosion at 1920 Leonard Ave., said Columbus Fire Battalion Chief Steve Martin. As firefighters pulled up to the second alarm fire, they were met by employees evacuating the building.
Materials stored onsite include maleic anhydride, phthalic anhydride, xylene, and mineral spirits, CSB officials said. The company has not yet provided the quantities of the material at the facility at the time of the incident. At the time of the incident, the OPC Polymer unit was engaged in normal operations. The material being produced was manufactured in a batch process.
Wendell Light, 44, of Heath, died in the blast. He was found around 9:15 a.m. April 8 and was partially covered in rubble inside the collapsed building, Martin said. He was pronounced dead at the scene.
Martin said Light was missing as the fire continued to burn. At daylight, fire crews were able to locate his body in the rubble, he said.
Light was a press room supervisor for Yenkin-Majestic Paint.
Because a portion of the building suffered damage in the explosion that started the fire, the search and rescue process took longer than expected, Martin said.
There were additional explosions as the fire burned, Martin said, including at least one at another building on the Majestic Paint campus that is within 100 feet of the primary building that burned.
All of the victims are employees at the plant.
The cause of the fire remains under investigation.
CSB officials said Yenkin-Majestic manufactures and markets industrial coatings that include acrylics, alkyds, coil and powder coatings, epoxies, primers, and urethanes and the company has 180 employees.
In addition, the OPC Polymer unit operates in a 24/7 operation and the site includes an adjacent paint manufacturing unit that operates 4/10 operation.
CSB reported the facility is covered by the Occupational Safety and Health Administration’s (OSHA) Process Safety Management (PSM) regulation due to the flammable liquids stored at the facility.


I used to work there and safety took a back seat if you go to yenkin majestic on Instagram you will see employees with there phone taking pics and doing video in one instance you can see 3 reactors decanter with the water ready to return to the kettle glad I don’t work there now
I worked there over 30 years Very dangerous work Most workers are inexperienced in this kind of work and the pay is lower than other companies doing related work Kettle 3 is the oldest of the kettles they have and most of the solvents they use now have a low boiling point Add to fast to resins that are still at a high temperature can create to much pressure Valves could be set wrong also to prevent release of pressure Resins have a recipe of certain chemicals if wrong ones are mixed this can create pressure The fact that the catch tank I believed was empty The kettle set up was wrong or failed Closed the kettle up and exploded