Rockwell Automation has an update to handle multiple vulnerabilities in its FactoryTalk AssetCentre, according to a report with CISA.
The vulnerabilities are OS command injection, deserialization of untrusted data, SQL injection, and improperly restricted functions. Successful exploitation of these remotely exploitable vulnerabilities, discovered by Sharon Brizinov and Amir Preminger of Claroty, may allow unauthenticated attackers to perform arbitrary command execution, SQL injection, or remote code execution.
Rockwell Automation said the vulnerabilities affects the following products: FactoryTalk AssetCentre, v10.00 and earlier.
In one issue, a deserialization vulnerability exists in how the AosService.rem service in FactoryTalk AssetCentre verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre.
CVE-2021-27462 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 10.0.
In addition, a deserialization vulnerability exists in how the ArchiveService.rem service in FactoryTalk AssetCentre verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre.
CVE-2021-27466 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 10.0.
Also, a deserialization vulnerability exists in how the LogService.rem service in FactoryTalk AssetCentre verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre.
CVE-2021-27470 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 10.0.
In another issue, FactoryTalk AssetCentre does not properly restrict all functions relating to IIS remoting services. This vulnerability may allow a remote, unauthenticated attacker to modify sensitive data in FactoryTalk AssetCentre.
CVE-2021-27474 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 10.0.
In addition, a vulnerability exists in the SaveConfigFile function of the RACompare Service, which may allow for OS command injection. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre.
CVE-2021-27476 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 10.0.
Also, a vulnerability exists in the RunSearch function of SearchService service, which may allow for the execution of remote unauthenticated arbitrary SQL statements.
CVE-2021-27472 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 10.0.
In another issue, the AosService.rem service exposes functions lacking proper authentication. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary SQL statements.
CVE-2021-27468 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 10.0.
In addition, the ArchiveService.rem service exposes functions lacking proper authentication. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary SQL statements.
CVE-2021-27464 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 10.0.
Also, FactoryTalk AssetCentre components contain .NET remoting endpoints that deserialize untrusted data without sufficiently verifying that the resulting data will be valid. This vulnerability may allow a remote, unauthenticated attacker to gain full access to the FactoryTalk AssetCentre main server and all agent machines.
CVE-2021-27460 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 10.0.
The product sees use mainly in the critical manufacturing sector. It also sees action on a global basis.
No known public exploits specifically target these vulnerabilities. However, an attacker with low skill level could leverage the vulnerabilities.
Rockwell encourages users of the affected versions of FactoryTalk AssetCentre to update to AssetCentre v11 (or above) to addresses these vulnerabilities. For more information about these vulnerabilities and mitigations please see Rockwell Automation’s publication KnowledgeBase ID: PN1559.
As an additional mitigation, Rockwell encourages users who are unable to upgrade or are concerned about unauthorized client connections to use built in security features found within FactoryTalk AssetCentre. Users should follow guidance found in QA46277. IPsec would minimize exposure to unauthorized clients and has been tested in FactoryTalk AssetCentre v9-v11.
- Rockwell recommends the following software/PC-based mitigation strategies:
- Run all software as User, not as an Administrator, to minimize the impact of malicious code on the infected system.
- Use of Microsoft AppLocker or other similar allow list applications can help mitigate risk. Information on using AppLocker with Rockwell Automation products is available at Knowledge Base Article QA17329.Â
- Ensure the least-privilege user principle is followed, and user/service account access to shared resources (such as a database) is only granted with a minimum number of rights as needed.
Rockwell recommends the following general mitigations:
- Use trusted software, software patches, antivirus/antimalware programs and interact only with trusted web sites and attachments.
- Minimize network exposure for all control system devices and/or systems and ensure they are not accessible from the Internet. For further information about the risks of unprotected Internet accessible control systems, see Knowledgebase Article PN715.Â
- Locate control system networks and devices behind firewalls and isolate them from the business network.
- When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize a VPN is only as secure as the connected devices.