Schneider Electric has a fix and mitigations available to a handle improper neutralization of input during web page generation (cross-site scripting) vulnerability in its Altivar products, ATVdPAC module, ILC992 InterLink Converter, according to a report with CISA.

Successful exploitation of this remotely exploitable vulnerability, discovered by Thomas Weber and David Blagojevic of CyberDanube, could allow an attacker to read or modify data.

In the issue, an improper neutralization of input during web page generation vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser.

CVE-2025-7746 is the case number for this vulnerability, which has a CVSS v3.1 base score of 6.1. There is also a CVSS v4 base score of 5.3.

Schneider reports the following products suffer from the issue:

Schneider Bold
  • Schneider Electric ATVdPAC module: Versions prior to 25.0
  • Schneider Electric Altivar Process Drives ATV930: All versions
  • Schneider Electric Altivar Process Drives ATV950: All versions
  • Schneider Electric Altivar Process Drives ATV955: All versions
  • Schneider Electric Altivar Process Drives ATV960: All versions
  • Schneider Electric Altivar Process Drives ATV980: All versions
  • Schneider Electric Altivar Process Drives ATV9A0: All versions
  • Schneider Electric Altivar Process Drives ATV9B0: All versions
  • Schneider Electric Altivar Process Drives ATV9L0: All versions
  • Schneider Electric Altivar Process Drives ATV991: All versions
  • Schneider Electric Altivar Process Drives ATV992: All versions
  • Schneider Electric Altivar Process Drives ATV993: All versions
  • Schneider Electric ILC992 InterLink Converter: All versions
  • Schneider Electric Altivar Machine Drives ATV340E: All versions
  • Schneider Electric Altivar Process Drives ATV6000 Medium Voltage: All versions
  • Schneider Electric Altivar Soft Starter ATS490: All versions
  • Schneider Electric Altivar Process Communication Modules VW3A3720: All versions
  • Schneider Electric Altivar Process Communication Modules VW3A3721: All versions
  • Schneider Electric Altivar Process Drives ATV630: All versions
  • Schneider Electric Altivar Process Drives ATV650: All versions
  • Schneider Electric Altivar Process Drives ATV660: All versions
  • Schneider Electric Altivar Process Drives ATV680: All versions
  • Schneider Electric Altivar Process Drives ATV6A0: All versions
  • Schneider Electric Altivar Process Drives ATV6B0: All versions
  • Schneider Electric Altivar Process Drives ATV6L0: All versions

The product sees use mainly in the critical manufacturing sector, and on a global basis.

Low Complexity Vulnerability

No exploit targets this vulnerability. However, an attacker could leverage this low complexity vulnerability.

Moreover, Schneider identified the following specific workarounds and mitigations users can apply to reduce risk:
Schneider Electric ATVdPAC module versions prior to 25.0, version 25.0 of VW3A3530D. Additionally, ATVdPAC module includes a fix for this vulnerability and is available upon request from Schneider’s Customer Care Center.

Furthermore, Schneider Electric ATVdPAC module versions prior to 25.0: If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: End user cybersecurity awareness and workstation protections, deactivate the webserver after use when not needed, setup network segmentation and implement a firewall to block all unauthorized access to port 80/HTTP, use VPN (Virtual Private Networks) tunnels if remote access is a requirement.

Remediation Plan

Additionally, Schneider is establishing a remediation plan for all future versions of these products that will include a fix: Schneider Electric ATV630 Altivar Process Drives All Versions, Schneider Electric ATV650 Altivar Process Drives All Versions, Schneider Electric ATV660 Altivar Process Drives All Versions, Schneider Electric ATV680 Altivar Process Drives All Versions, Schneider Electric ATV6A0 Altivar Process Drives All Versions, Schneider Electric ATV6B0 Altivar Process Drives All Versions, Schneider Electric ATV6L0 Altivar Process Drives All Versions, Schneider Electric ATV930 Altivar Process Drives All Versions, Schneider Electric ATV950 Altivar Process Drives All Versions, Schneider Electric ATV955 Altivar Process Drives All Versions, Schneider Electric ATV960 Altivar Process Drives All Versions, Schneider Electric ATV980 Altivar Process Drives All Versions, Schneider Electric ATV9A0 Altivar Process Drives All Versions, Schneider Electric ATV9B0 Altivar Process Drives All Versions, Schneider Electric ATV9L0 Altivar Process Drives All Versions, Schneider Electric ATV991 Altivar Process Drives All Versions, Schneider Electric ATV992 Altivar Process Drives All Versions, Schneider Electric ATV993 Altivar Process Drives All Versions, Schneider Electric ILC992 InterLink Converter All Versions, Schneider Electric ATV340E Altivar Machine Drives All Versions, Schneider Electric ATV6000 Medium Voltage Altivar Process Drives All Versions, Schneider Electric ATS490 Altivar Soft Starter All Versions, Schneider Electric Altivar Process Communication Modules All Versions.

Meanwhile, until then, users should immediately apply the following mitigations to reduce the risk of exploit: End user cybersecurity awareness and workstation protections, deactivate the webserver after use when not needed, setup network segmentation and implement a firewall to block all unauthorized access to port 80/HTTP, use VPN (virtual private networks) tunnels if remote access is a requirement.

More Information

For more information see the associated Schneider Electric CPCERT security advisory SEVD-2025-252-01 Multiple Altivar Process Drives and Communication Modules – SEVD-2025-252-01 PDF Version, Multiple Altivar Process Drives and Communication Modules – SEVD-2025-252-01 CSAF Version.

 

Pin It on Pinterest

Share This