Schneider Electric has an update available to handle an improper restriction of excessive authentication attempts in its PowerChute Serial Shutdown, according to a report with CISA.

The PowerChute Serial Shutdown product is UPS management software enabling graceful system shutdown and energy management capabilities for desktops, servers and workstations.

There is an improper authentication validation vulnerability, which Schneider self-reported, that could lead to an attacker disrupting operations and gaining access to system data.

The following versions of Schneider Electric PowerChute Serial Shutdown are affected: Up to and including 1.5.

In the vulnerability, there is an improper restriction of excessive authentication attempts vulnerability that could allow an attacker to gain unauthorized access to a user account by performing an arbitrary number of authentication attempts when redirect handling is disabled.

Schneider Bold

CVE-2026-13348 is the case number for the vulnerability, which has a CVSS V3 base score of 5.3.

The product sees use in the commercial facilities, critical manufacturing, energy, and information technology sectors, and on a global basis.

Mitigations

In terms of mitigations:

Version v1.6 of PowerChute Serial Shutdown includes a fix for these vulnerabilities and is available for download for the Windows version. Reboot needed: Upon installation, the service automatically restarts. A user can validate a successful install by checking the version information in the Control Panel or on the About page within PCSS after logging in. Click here for specific instructions and hardening guidelines for these remediations.

Version v1.6 of PowerChute Serial Shutdown includes a fix for these vulnerabilities and is available in Linux. Reboot needed: Upon installation, the service automatically restarts. A customer can validate a successful install by checking the version information in the Control Panel or on the About page within PCSS after logging in. Click here for specific instructions and hardening guidelines for these remediations.

For more information see the associated Schneider Electric security advisory Improper Restriction of Excessive Authentication Attempts vulnerability on PowerChute Serial Shutdown – SEVD-2026-223-01

Best Pratices

Schneider recommends the following industry cybersecurity best practices.

  • Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
  • Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
  • Place all controllers in locked cabinets and never leave them in the “Program” mode.
  • Never connect programming software to any network other than the network intended for that device.
  • Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
  • Never allow mobile devices that connected to any other network besides the intended network connect to the safety or control networks without proper sanitation.
  • Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.
  • When remote access is a requirement, use secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities and should end up updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.

For more information click on the Schneider Electric Recommended Cybersecurity Best Practices document.