Siemens has mitigations available to handle out-of-bounds write and use of out-of-range pointer offset vulnerabilities in its Nucleus NET, Nucleus RTOS, Nucleus Source Code, and VSTAR, according to a report with CISA.

Successful exploitation of these remotely exploitable vulnerabilities, discovered by Daniel dos Santos from Forescout Technologies, could allow a denial-of-service condition or for the execution of code remotely.

The following Nucleus products suffer from the issue:

  • Nucleus NET: All versions prior to v5.2
  • Nucleus RTOS: Versions including affected DNS modules
  • Nucleus Source Code: Versions including affected DNS modules
  • VSTAR: Versions including affected DNS modules

In one issue, the DNS domain name label parsing functionality does not properly validate the names in DNS-responses. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.

Schneider Bold

CVE-2020-15795 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.1.

In addition, the DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.

CVE-2020-27009 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.1.

The product sees use in multiple industrial sectors, and on a global basis.

No known public exploits specifically target these vulnerabilities. However, since the vulnerability has low complexity, an attacker could leverage the issue.

Siemens published security advisory SSA-185699 and released the following mitigations for the affected products:

  • Nucleus NET: Follow general security measures or upgrade to the latest versions of Nucleus ReadyStart or Nucleus 4. Note the latest version of Nucleus NET (v5.2) is not affected by the vulnerabilities but is already beyond end of software support
  • Nucleus RTOS: Contact customer support to receive patch and update information 
  • Nucleus Source Code: Contact customer support to receive patch and update information 
    VSTAR: Contact customer support to receive patch and update information 

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • Avoid using DNS client of affected versions
  • For additional mitigation advice contact Siemens customer support or a Nucleus Sales team
  • As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms.

In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens’ Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.

Click here for additional information on industrial security by Siemens.

For further inquiries on security vulnerabilities in Siemens’ products and solutions, contact Siemens ProductCERT.

Pin It on Pinterest