Siemens has an update available to handle multiple vulnerabilities in its RUGGEDCOM CROSBOW, according to a report with CISA.

The vulnerabilities are improper neutralization of special elements used in an SQL command (SQL Injection), authorization bypass through user-controlled key, insertion of sensitive information into sent data, and client-side enforcement of server-side security.

These vulnerabilities, which Siemens self-reported, could allow an attacker to execute arbitrary SQL commands on the underlying database, retrieve sensitive administrative credentials, escalate privileges, and perform unauthorized operations such as modifying system configurations or causing a denial of service.

Siemens RUGGEDCOM CROSSBOW is an enterprise-class, vendor-agnostic Secure Access Management (SAM) solution designed for critical infrastructure sectors like electric power utilities, oil and gas, renewables, and rail.

The following versions of Siemens RUGGEDCOM CROSSBOW suffer from the vulnerabilities: Versions up to 6.0.

Schneider Bold
Vulnerabilities

In one issue, affected devices do not properly validate or sanitize input in facility names processed during the Bulk Import/Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.

CVE-2026-89196 is the case number for the vulnerability, which has a CVSS V3 base score of 8.8.

Additionally, affected devices do not properly validate or sanitize input in the Value field of notification conditions processed during the Notification Profile configuration. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.

CVE-2026-89197 is the case number for the vulnerability, which has a CVSS V3 base score of 8.8.

Also, affected devices do not properly validate or sanitize the filename of firmware files uploaded to the system. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.

CVE-2026-89198 is the case number for the vulnerability, which has a CVSS V3 base score of 8.8.

Meanwhile, affected devices do not properly restrict access to sensitive configuration items via specific database queries. This could allow an authenticated attacker to retrieve administrative credentials for various internal systems, leading to unauthorized information disclosure and privilege escalation.

CVE-2026-89199 is the case number for the vulnerability, which has a CVSS V3 base score of 8.8.

Moreover, affected devices do not properly validate or sanitize input in the Name and Value fields for custom file labels. This could allow an authenticated attacker with administrative privileges to execute arbitrary SQL commands on the underlying database.

CVE-2026-89200 is the case number for the vulnerability, which has a CVSS V3 base score of 6.7.

Bulk Export Issue

Furthermore, affected devices do not properly validate or sanitize input in device group or facility names processed during the Bulk Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.

CVE-2026-89201 is the case number for the vulnerability, which has a CVSS V3 base score of 7.5.

Indeed, affected devices do not properly perform authorization checks for device disconnection requests. This could allow an authenticated attacker with minimal privileges to disconnect active sessions of other users, including administrators, leading to a denial of service.

CVE-2026-89202 is the case number for the vulnerability, which has a CVSS V3 base score of 6.5.

In another issue, affected devices do not properly restrict access to various database queries, allowing users to retrieve system-wide information not intended for their privilege level. This could allow an authenticated attacker to gather sensitive information about the system’s infrastructure, including details on all devices, substations, users, and scheduled activities.

CVE-2026-89203 is the case number for the vulnerability, which has a CVSS V3 base score of 4.3.

Additionally, affected devices do not properly restrict access to database queries used for subnet management. This could allow an authenticated attacker to read, modify, or delete subnet configurations, leading to unauthorized information disclosure and data manipulation.

CVE-2026-89204 is the case number for the vulnerability, which has a CVSS V3 base score of 5.4.

Also, affected devices do not properly perform server-side authorization checks for requests to schedule special operations. This could allow an authenticated attacker with minimal privileges to schedule unauthorized operations on devices.

CVE-2026-89205 is the case number for the vulnerability, which has a CVSS V3 base score of 6.3.

Authorization Checks

Meanwhile, affected devices do not properly perform server-side authorization checks for requests to modify the state of scheduled actions. This could allow an authenticated attacker with minimal privileges to retry, stop, or delete scheduled tasks without proper authorization.

CVE-2026-89206 is the case number for the vulnerability, which has a CVSS V3 base score of 6.3.

The product sees use in the critical manufacturing, transportation systems, energy, healthcare and public health, financial services, and government services and facilities. It also sees action on a global basis.

In terms of mitigations, for affected RUGGEDCOM CROSSBOW versions up to V6.0, update to V6.0 or later.

As a general security measure, Siemens recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens’ operational guidelines for Industrial Security.

Click here for additional information on Industrial Security by Siemens.

Click here to view other Siemens product security fixes.