Successful exploitation of these vulnerabilities, discovered by Xina1i working with Trend Micro’s Zero Day Initiative, could lead the application to crash, or to arbitrary code execution and data extraction on the target host system.
Solid Edge SE2021: All versions prior to SE2021MP7 suffer from the vulnerabilities.
In one issue, an XML external entity injection vulnerability in the underlying XML parser could cause the affected application to disclose arbitrary files to remote attackers by loading a specially crafted XML file.
CVE-2021-37178 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 5.6.
In addition, the PSKERNEL.DLL library in the affected application lacks proper validation while parsing user-supplied OBJ files that could lead to a use-after-free condition. An attacker could leverage this vulnerability to execute code in the context of the current process.
CVE-2021-37179 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.8.
Also, the PSKERNEL.DLL library lacks proper validation while parsing user supplied OBJ files that could cause an out-of-bounds access to an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process.
CVE-2021-37180 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.8.
The product sees use mainly in the critical manufacturing sector, and on a global basis.
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely. However, an attacker with low skill level could leverage these low complexity vulnerabilities.
Siemens released updates for the following products: Solid Edge SE2021: Update to SE2021MP7 or later version (login required).
Siemens found workarounds and mitigations users can apply to reduce the risk: Avoid opening files from unknown sources in Solid Edge.
As a general security measure, Siemens recommends users protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends users configure the environment according to Siemens’ operational guidelines for industrial security and follow the recommendations in the product manuals.
Click here for additional information on industrial security by Siemens.
For more information about this issue, click on Siemens Security Advisory SSA-818688.