Siemens has updates available to handle uncontrolled resource consumption and improper input validation in its RUGGEDCOM, SCALANCE, SIMATIC, and SINEMA products, according to a report with CISA.
Successful exploitation of these remotely exploitable vulnerabilities could allow remote attackers to affect the availability of the devices under certain conditions. Siemens reported these publicly known vulnerabilities also affect these products.
The products see use in the chemical, energy, food and agriculture, and water and wastewater systems sectors. They also see action on a global basis. No known public exploits specifically target these vulnerabilities. However, an attacker with low skill level could leverage the vulnerabilities.
The following Siemens products suffer from the vulnerabilities:
- RUGGEDCOM RM1224: All versions prior to 6.1
- RUGGEDCOM ROX II: All versions prior to 2.13.3 (only affected by CVE-2018-5391)
- SCALANCE M-800 family: All versions prior to 6.1
- SCALANCE S615: All versions prior to 6.1
- SCALANCE SC-600: All versions prior to 2.0
- SCALANCE W1700 IEEE 802.11ac: All versions prior to 2.0
- SCALANCE W700 IEEE 802.11a/b/g/n: All versions prior to 6.4
- SIMATIC CP 1242-7: All versions prior to 3.2
- SIMATIC CP 1243-1 (incl. SIPLUS NET variants): All versions prior to 3.2
- SIMATIC CP 1243-7 LTE EU: All versions prior to 3.2
- SIMATIC CP 2243-7 LTE US: All versions prior to 3.2
- SIMATIC CP 1243-8 IRC: All versions prior to 3.2
- SIMATIC CP 1542SP-1: All versions prior to 2.1
- SIMATIC CP 1542SP-1 IRC (incl. SIPLUS NET variants): All versions prior to 2.1
- SIMATIC CP 1543-1 (incl. SIPLUS NET variants): All versions prior to 2.2
- SIMATIC CP 1543SP-1 (incl. SIPLUS NET variants): All versions prior to 2.1
- SIMATIC RF185C: All versions
- SIMATIC RF186C: All versions
- SIMATIC RF186CI: All versions
- SIMATIC RF188C: All versions
- SIMATIC RF188CI: All versions
- SINEMA Remote Connect Server: All versions newer than 1.1 and prior to 2.0.1
In one vulnerability, certain Linux kernel versions can end up forced to make resource intensive calls for every incoming packet, which can lead to a denial-of-service condition.
CVE-2018-5390 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
In addition, certain Linux kernels are vulnerable to a denial-of-service attack with low rates of specially modified packets targeting IP fragment re-assembly. An attacker may cause a denial-of-service condition by sending specially crafted IP fragments.
CVE-2018-5391 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
Siemens recommended applying updates, where available:
Siemens did not identify any specific mitigations or workarounds and recommends following their general security recommendations. As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens operational guidelines for Industrial Security and following the recommendations in the product manuals.
For additional information, please refer to Siemens Security Advisory SSA-377115.

