Siemens has new versions available to handle an improper protection against electromagnetic fault injection (EM-FI) vulnerability in its LOGO! and SIPLUS LOGO! products, according to a report with CISA.

Successful exploitation of this vulnerability, which Siemens self-reported, could cause an electromagnetic fault injection, which would allow an attacker to dump and debug the firmware including memory manipulation.

In the issue, affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow an attacker to inject public keys of custom created key pairs which then end up signed by the product Certificate Authority (CA). The generation of a custom certificate allows communication with, and impersonation of, any device of the same version.

CVE-2022-42784 is the case number for this vulnerability, which has a CVSS v3 base score of 7.6.

The following products of suffer from the issue:

Schneider Bold
  • LOGO! 12/24RCE (6ED1052-1MD08-0BA1): Versions v8.3 and prior
  • LOGO! 12/24RCEo (6ED1052-2MD08-0BA1): Versions v8.3 and prior
  • LOGO! 24CE (6ED1052-1CC08-0BA1): Versions v8.3 and prior
  • LOGO! 24CEo (6ED1052-2CC08-0BA1): Versions v8.3 and prior
  • LOGO! 24RCE (6ED1052-1HB08-0BA1): Versions v8.3 and prior
  • LOGO! 24RCEo (6ED1052-2HB08-0BA1): Versions v8.3 and prior
  • LOGO! 230RCE (6ED1052-1FB08-0BA1): Versions v8.3 and prior
  • LOGO! 230RCEo (6ED1052-2FB08-0BA1): Versions v8.3 and prior
  • SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1): Versions v8.3 and prior
  • SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1): Versions v8.3 and prior
  • SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1): Versions v8.3 and prior
  • SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1): Versions v8.3 and prior
  • SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1): Versions v8.3 and prior
  • SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1): Versions v8.3 and prior
  • SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1): Versions v8.3 and prior
  • SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1): Versions v8.3 and prior

The product sees use in multiple industrial sectors, and on a global basis.

No known public exploits targeting this vulnerability. This vulnerability is not exploitable remotely. However, an attacker could leverage this low complexity vulnerability.

The vulnerability ends up related to the specific hardware architecture of the LOGO! V8.3 BM. Siemens released new hardware versions with the LOGO! V8.4 BM product family for several affected devices which fixed the vulnerability and where they rotated the Product CA private key. Siemens is working on new hardware versions for the SIPLUS devices to address this issue further.

Siemens identified the following specific workarounds and mitigations users can apply to reduce risk:

  1. Use HTTPS communication only in trusted networks without unknown network devices
  2. If possible, connect the Base Module directly with LOGO! Soft Comfort and the Web Browser

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

For more information click on the associated Siemens security advisory SSA-844582.