Siemens has updates available to handle multiple vulnerabilities in SINUMERIK, according to a report with CISA.
The vulnerabilities are a buffer underflow, heap-based buffer overflow, improper initialization, out-of-bounds read, stack-based buffer overflow, access of memory location after end of buffer, off-by-one error, improper null termination and improper initialization. Successful exploitation of these remotely exploitable vulnerabilities, which Siemens self-reported, could allow remote code execution, information disclosure, and denial-of-service attacks under certain conditions.
Siemens reports the vulnerabilities affect the following SINUMERIK products:
- SINUMERIK Access MyMachine/P2P: All versions prior to 4.8
- SINUMERIK PCU base Win10 software/IPC: All versions prior to 14.00
- SINUMERIK PCU base Win7 software/IPC: All versions prior to 12.01 HF4
In one issue, the affected products are vulnerable to a buffer underwrite in VNC client code, which may allow an attacker to remotely execute arbitrary code.
CVE-2018-15361 is the case number assigned to this vulnerability, which has CVSS v3 base score of 9.8.
In addition, the affected products are vulnerable to a heap-based buffer overflow, which may result in code execution.
CVE-2019-8258 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
Also, the affected products contain multiple memory leaks in VNC client code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR.
CVE-2019-8259 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
In another issue, there is an out-of-bounds read vulnerability in VNC client decoder code caused by multiplication overflow.
CVE-2019-8260 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
In addition, the affected products have an out-of-bounds read vulnerability in VNC code inside the client decoder, caused by multiplication overflow.
CVE-2019-8261 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
Also, the affected products have multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which results in code execution.
CVE-2019-8262 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
In another issue, the affected products are vulnerable to a stack-based buffer overflow, which leads to a denial-of-service condition. User interaction is required to trigger this vulnerability.
CVE-2019-8263 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 6.5.
In addition, the affected products are vulnerable due to out-of-bounds access, which can potentially result in code execution.
CVE-2019-8264 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
Also, the affected products are vulnerable to multiple out-of-bounds access vulnerabilities connected with usage of a macro in the VNC client code, which can potentially result in code execution.
CVE-2019-8265 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
In another issue, the affected products have multiple out-of-bounds access vulnerabilities connected with improper usage of functions in the VNC client code, which can potentially result in code execution.
CVE-2019-8266 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
In addition, the affected products are vulnerable due to an out-of-bounds read in the VNC client code, which may result in a denial-of-service condition.
CVE-2019-8267 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
Also, the affected products have multiple off-by-one vulnerabilities in VNC client code connected with improper usage of functions, which can potentially result code execution.
CVE-2019-8268 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
In another issue, the affected products are vulnerable to a stack-based buffer overflow in the VNC client code, which may allow an attacker to perform a denial of service condition.
CVE-2019-8269 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
In addition, the affected products have an out-of-bounds read vulnerability in VNC client code inside Ultra decoder, which results in a denial-of-service condition.
CVE-2019-8270 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
Also, the affected products are vulnerable to a heap-based buffer overflow in the VNC server code inside the file transfer handler, which can potentially result in code execution.
CVE-2019-8271 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
In another issue, the affected products are vulnerable to multiple off-by-one errors in the VNC server code, which may allow an attacker to execute arbitrary code.
CVE-2019-8272 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
In addition, the affected products are vulnerable to a heap-based buffer overflow in the VNC server code inside the file transfer request handler, which can potentially result in code execution.
CVE-2019-8273 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
Also, the affected products have a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution.
CVE-2019-8274 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
In yet another issue, there is an improper null termination in the VNC server code, which may allow remote access to out-of-bounds data.
CVE-2019-8275 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
In addition, the affected products are vulnerable to a stack-based buffer overflow in the VNC server code, which can result in denial of service.
CVE-2019-8276 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
Also, the affected products contain multiple memory leaks in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR.
CVE-2019-8277 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
Finally, the affected products are vulnerable to out-of-bounds access in the VNC client, which can potentially allow code execution.
CVE-2019-8280 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
The product sees use in the chemical, energy, food and agriculture, and water and wastewater systems sectors. It also sees action on a global basis.
No known public exploits specifically target these vulnerabilities. However, an attacker with low skill level could leverage the vulnerabilities.
Siemens released updates for the affected products and recommends users update to the latest versions:
- SINUMERIK Access MyMachine/P2P: Update to v4.8 (SINUMERIK software can be obtained from a Siemens account manager)
- SINUMERIK PCU base Win10 software/IPC: Update to v14.00 (SINUMERIK software can be obtained from a Siemens account manager)
- SINUMERIK PCU base Win7 software/IPC: Update to v12.01 HF4 (SINUMERIK software can be obtained from a Siemens account manager)
Siemens recommends the following to help reduce risk: Restrict access to the device to the internal or VPN network and to trusted IP addresses only.
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to the Siemens operational guidelines for Industrial Security and following the recommendations in the product manuals.
For additional information, click on Siemens Security Advisory SSA-927095.