Siemens has a mitigation plan to handle an infinite loop vulnerability in its Nucleus 4, Nucleus NET, Nucleus ReadyStart, Nucleus Source Code, and VSTAR, according to a report with CISA.
Successful exploitation of these remotely exploitable vulnerabilities, which Siemens self-reported, could cause a denial-of-service condition.
The following Nucleus products suffer from the issue:
- Nucleus 4: All versions prior to v4.1.0
- Nucleus NET: All versions
- Nucleus ReadyStart: All versions
- Nucleus Source Code: Versions including the affected IPv6 stack
- VSTAR: Versions including the affected IPv6 stack
In one issue, the function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values.
CVE-2021-25663 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
In addition, the function that processes the hop-by-hop extension header in IPv6 packets and its options lacks any checks against the length field of the header, allowing attackers to put the function into an infinite loop by supplying arbitrary length values.
CVE-2021-25664 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
The product sees use in multiple industrial sectors, and it sees action on a global basis.
No known public exploits specifically target these vulnerabilities. However, an attacker with low skill level could leverage these low complexity attacks.
Siemens published security advisory SSA-248289 and released the following mitigations for the affected products:
- Nucleus 4: Update to v4.1.0 or later version (login required)
- Nucleus NET: Contact customer support or the Nucleus Sales team or upgrade to the latest versions of Nucleus ReadyStart or Nucleus 4.
- Nucleus ReadyStart: Contact customer support or the Nucleus Sales team
- Nucleus Source Code: Contact customer support to receive patch and update informationÂ
- VSTAR: Contact customer support to receive patch and update information
Siemens identified the following specific workarounds and mitigations that users can apply to reduce the risk: For additional mitigation advice contact customer support or the Nucleus Sales team.
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ Operational Guidelines for Industrial Security, and following the recommendations in the product manuals.
Click here for additional information on industrial security by Siemens.
For further inquiries on security vulnerabilities in Siemens’ products and solutions, contact Siemens ProductCERT.