Siemens has updates available to handle out-of-bounds read and NULL pointer dereference vulnerabilities in its Parasolid, according to a report with CISA.

Successful exploitation of these vulnerabilities, which Siemens self-reported, could allow an attacker to leverage the vulnerability to perform remote code execution in the context of the current process.

The following products of Siemens suffer from the vulnerabilities:
— Parasolid V35.0: all versions prior to V35.0.263
— Parasolid V35.0: all versions prior to V35.0.251
— Parasolid V35.1: all versions prior to V35.1.252
— Parasolid V35.1: all versions prior to V35.1.170
— Parasolid V36.0: all versions prior to V36.0.198

In one issue, the affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process.

CVE-2023-49125 is the case number for this vulnerability, which has a CVSS v3 base score of 7.8.

Schneider Bold

There is also a CVSS v4 score calculated for CVE-2023-49125, which is 7.3.

In addition, the affected applications contain a null pointer dereference vulnerability while parsing specially crafted XT files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.

CVE-2024-22043 is the case number for this vulnerability, which has a CVSS v3 base score of 3.3.

There is also a CVSS v4 score calculated for CVE-2023-49125, which is 4.8.

The product sees use mainly in the critical manufacturing sector, and on a global basis.

No known public exploits target these vulnerabilities. These vulnerabilities are not exploitable remotely. However, an attacker could leverage these low complexity vulnerabilities.

Siemens released new versions for the affected products and recommends to update to the latest versions:

Siemens identified the following specific workarounds and mitigations users can apply to reduce risk: Do not open untrusted XT files in Parasolid.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

For more information see the associated Siemens security advisory SSA-797296.