The vulnerabilities include NULL pointer dereference, out-of-bounds read, out-of-bounds write, allocation of resources without limits or throttling.
An attacker could successfully exploit these vulnerabilities, which Siemens self-reported, by tricking a user into opening a malicious file, allowing the attacker to cause a denial of service or perform remote code execution in the context of the current process.
Siemens reports the following products suffer from the vulnerabilities:
- Parasolid V34.1: versions prior to V34.1.258
- Parasolid V35.0: versions prior to V35.0.254
- Parasolid V35.1: versions prior to V35.1.171
- Parasolid V35.1: versions prior to V35.1.197
- Parasolid V35.1: versions prior to V35.1.184
- Teamcenter Visualization V14.1: all versions
- Teamcenter Visualization V14.2: versions prior to V14.2.0.6
- Teamcenter Visualization V14.3: all versions
In one issue, the affected applications contain null pointer dereference while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-38524 is the case number for this vulnerability, which has a CVSS v3 base score of 3.3.
In addition, the affected applications contain an out-of-bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-38525 is the case number for this vulnerability, which has a CVSS v3 base score of 7.8.
Also, the affected applications contain an out-of-bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-38526 is the case number for this vulnerability, which has a CVSS v3 base score of 7.8.
Meanwhile, the affected applications contain an out-of-bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-38527 is the case number for this vulnerability, which has a CVSS v3 base score of 7.8.
In another issue, the affected applications contain an out-of-bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-38529 is the case number for this vulnerability, which has a CVSS v3 base score of 7.8.
In addition, the affected applications contain an out-of-bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-38530 is the case number for this vulnerability, which has a CVSS v3 base score of 7.8.
Also, the affected applications contain an out-of-bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-38531 is the case number for this vulnerability, which has a CVSS v3 base score of 7.8.
Meanwhile, the affected application contains an out-of-bounds write past the end of an allocated buffer while parsing a specially crafted X_T file. This could allow an attacker to execute code in the context of the current process.
CVE-2023-38528 is the case number for this vulnerability, which has a CVSS v3 base score of 7.8.
In another issue, the affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition.
CVE-2023-38532 is the case number for this vulnerability, which has a CVSS v3 base score of 6.6.
The product sees use mainly in the critical manufacturing sector, and on a global basis.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. These vulnerabilities have low attack complexity.
Siemens released updates for several affected products and recommends updating to the latest versions. Siemens is preparing further updates for Teamcenter Visualization V14.1 and V14.3.
- Parasolid V34.1: Update to V34.1.258 or later versionÂ
- Parasolid V35.0: Update to V35.0.254 or later versionÂ
- Parasolid V35.1: Update to V35.1.171 or later versionÂ
- Parasolid V35.1: Update to V35.1.197 or later versionÂ
- Parasolid V35.1: Update to V35.1.184 or later versionÂ
- Teamcenter Visualization V14.2: Update to V14.2.0.6 or later version
Siemens identified the following specific workaround/mitigation users can apply to reduce risk: Do not open untrusted X_T files in Parasolid or Teamcenter Visualization.
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to the Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
For more information, click on the associated Siemens security advisory SSA-407785.