Siemens has workarounds and mitigations to handle multiple vulnerabilities in its SiNVR 3, according to a report with CISA.

The vulnerabilities are a path traversal, cleartext storage in a file or on disk, SQL injection, cross-site scripting, insufficient logging improper input validation, and weak cryptography for passwords.

Successful exploitation of these remotely exploitable vulnerabilities, which Siemens self-reported, could result in unauthorized access to server data and possible denial-of-service conditions.

The following versions of SiNVR 3, a video management platform, suffer from the issues:

  • SiNVR 3 Central Control Server (CCS): all versions
  • SiNVR 3 Video Server: all versions
  • In one issue, successful exploitation could allow an authenticated remote attacker to access and download arbitrary files from the server.

    CVE-2019-19290 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 6.5.

    In addition, the affected product maintains a log file that stores login credentials in cleartext. Authenticated remote attackers could extract login credentials of other users of the service.

    CVE-2019-19291 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 5.3.

    Also, the affected product contains an SQL injection vulnerability in its XML-based communication protocol as provided by default. An authenticated remote attacker could read or modify the database and execute administrative database operations or operating system commands.

    CVE-2019-19292 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.8.

    In another issue, the affected product contains a reflected cross-site scripting (XSS) vulnerability that could allow an unauthenticated remote attacker to steal sensitive data or execute administrative actions on behalf of a legitimate administrator.

    CVE-2019-19293 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 6.1.

    In addition, the affected product contains multiple stored cross-site scripting (XSS) vulnerabilities in several input fields. This could allow an authenticated remote attacker to inject malicious JavaScript code.

    CVE-2019-19294 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 6.3.

    Also, the affected device does not enforce logging of security-relevant activities in the XML-based communication protocol. An authenticated remote attacker could perform covert actions not visible in the application log.

    CVE-2019-19295 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 4.3.

    In another issue, successful exploitation could allow an authenticated remote attacker to access and download arbitrary files from the server, if the FTP services are enabled.

    CVE-2019-19296 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 6.8.

    In a path traversal issue, successful exploitation could allow an authenticated remote attacker to access and download arbitrary files from the server.

    CVE-2019-19297 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.

    In an improper input validation vulnerability, successful exploitation could allow an unauthenticated remote attacker to cause a denial-of-service condition by sending malformed HTTP requests.

    CVE-2019-19298 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.

    In addition, the affected product contains weak cryptography when exposing device passwords. This could allow an unauthenticated remote attacker to read and decrypt the passwords and conduct further attacks.

    CVE-2019-19299 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.

    The product sees use mainly in the information technology sector, however on a global basis.

    No known public exploits specifically target these vulnerabilities. However, an attacker with low skill level could leverage the vulnerabilities.

    Siemens identified the following specific workarounds and mitigations users can apply to reduce the risk:

  • Apply ACL/firewall configuration on the SiNVR Video and CCS servers to ensure only legitimate SiNVR systems can access the configured video/CCS server ports.
  • Harden all SiNVR systems accordingly to prevent unauthorized access.
  • Consider applying encryption and authentication on the network (e.g., via TLS on application level or via IPSec on host level).
  • Disable the web interface of CCS if not used. Alternatively, restrict access from local host only, or only to trusted hosts of CCS administrators.
  • Enable TLS for the web interface of CCS.
  • Disable the FTP service of the CCS.
  • Disable the two FTP services of the video server.
  • As a general security measure Siemens recommends protecting network access to affected products with appropriate mechanisms. Siemens advises users to follow recommended security practices in order to run the devices in a protected IT environment.

    Click here for additional information on industrial security by Siemens.

    For further inquiries on security vulnerabilities in Siemens products and solutions, click on Siemens ProductCERT.

    For more information on these vulnerabilities, please see Siemens security advisory SSA-844761.

    Schneider Bold