Siemens has workarounds and mitigations for improper neutralization of script-related HTML tags in a web page (Basic XSS) and cross-site request forgery (CSRF) vulnerabilities, but will not fix its Polarion Subversion Webclient because it is no longer supported.

Successful exploitation of these remotely exploitable vulnerabilities, discovered by Li Yifan, where an attacker injects client-side script to induce the victim to issue an HTTP request could lead to a state-changing operation. The following versions of Siemens Polarion Subversion Webclient are affected: All versions.

In one vulnerability, the Polarion Subversion Webclient application does not filter user input in a way that prevents cross-site scripting (XSS). If a user is enticed into passing specially crafted malicious input to the web client (e.g., by clicking on a malicious URL with embedded JavaScript), JavaScript code can be returned and executed by the user’s client. Various actions could end up triggered by running malicious JavaScript code.

CVE-2020-15788 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 6.1.

In addition, the web interface could allow a CSRF attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface the legitimate user is allowed to perform. This could allow the attacker to read or modify contents of the web application.

Schneider Bold

CVE-2020-15789 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.1.

The product sees use mainly in the energy sector. Is also sees action on a global basis.

No known public exploits specifically target these vulnerabilities. However, an attacker with low skill level could leverage the vulnerabilities.

Siemens said the tool is considered shareware, distributed “as is,” and will be no fix as it is no longer supported.

Siemens has identified the following specific workaround and mitigation users can apply to reduce the risk: Do not open unknown links while working on Polarion Subversion Webclient.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens operational guidelines for Industrial Security and following the recommendations in the product manuals.

For additional information, please refer to Siemens Security Advisory SSA-436520.

Pin It on Pinterest

Share This