Siemens has an update for an exposure of sensitive information to an unauthorized actor vulnerability in its RUGGEDCOM APE1808, according to a report with CISA.

Successful exploitation of this remotely exploitable vulnerability, which Siemens self-reported, could allow an unauthenticated attacker to obtain assets data without authentication.

The following products with Nozomi Guardian/CMC suffer from the issue: RUGGEDCOM APE1808, all versions prior to 23.3.0.

In the vulnerability, a missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication.

CVE-2023-5253 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 5.3.

Schneider Bold

The product sees use mainly in the critical manufacturing sector, and on a global basis.

No known public exploit targets this vulnerability. However, an attacker could leverage this low complexity vulnerability.

In terms of mitigations, Siemens recommends the following:

  • Contact customer support to receive patch and update information
  • Use internal firewall features to limit access to the web management interface

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

For more information see the associated Siemens security advisory SSA-665034.