Successful exploitation of this vulnerability, which Siemens self-reported, could allow a privileged local user to escalate privileges. Siemens said the vulnerabilities affect the following versions of SIMATIC RTLS Locating Manager: All versions prior to v2.10.2.
In one vulnerability, the start-stop scripts for the services of the affected application could allow a local attacker to include arbitrary commands executed when services are started or stopped interactively by system administrators.
CVE-2020-10049 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.9.
In addition, the directory of service executables of the affected application could allow a local attacker to include arbitrary commands executed with system privileges when the system restarts.
CVE-2020-10050 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.4.
Also, multiple services of the affected application end up executed with system privileges while the call path is not quoted. This could allow a local attacker to inject arbitrary commands that end up executed instead of the legitimate service.
CVE-2020-10051 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.4.
The product sees use in the critical manufacturing and transportation systems sectors. It also sees action on a global basis.
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely. However, an attacker with low skill level could leverage the vulnerabilities.
Siemens recommends users apply the update of the SIMATIC RTLS Locating Manager: v2.10.2.Â
In addition, Siemens discovered the following specific workarounds and mitigations users can apply to reduce the risk:
- Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines
- Ensure only trusted persons have access to the system and avoid the configuration of additional local accounts on the server
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for Industrial Security, and following the recommendations in the product manuals.
Click on this link for additional information on Industrial Security by Siemens.
For more information on these vulnerabilities and the associated mitigations, click on Siemens security advisory SSA-251935.