Successful exploitation of these remotely exploitable vulnerabilities, discovered by Deniz Cevik from Cyberwise Turkiye and Michael Heinzl, could allow unauthenticated access or privilege escalation.
Siemens reports that the following products suffer from the vulnerabilities: Polarion ALM, all versions.
In one issue, Siemens Polarion ALM is vulnerable due to weak file and folder permissions in the installation path. An attacker with local access could exploit this vulnerability to escalate privileges to NT AUTHORITY\SYSTEM.
CVE-2023-50236 is the case number for vulnerability, which has a CVSS v3 base score of 7.8.
There is also a CVSS v4 score calculated for CVE-2023-50236, which is 8.5.
In addition, the REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.
CVE-2024-23813 is the case number for this vulnerability, which has a CVSS v3 base score of 7.3.
There is also a CVSS v4 score calculated for CVE-2024-23813, which is 6.9.
The product sees use mainly in the critical manufacturing sector, and on a global basis.
No known public exploits target these vulnerabilities. However, an attacker could leverage these low complexity vulnerabilities.
Siemens is preparing fix versions and recommends countermeasures for products where fixes are not yet available.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- An administrator can restrict the file and folder path permissions post installation.
- If DOORS connector does not see use in the environment, add the following in the Apache configuration to restrict unauthenticated access: <If “%{REQUEST_URI} =~ m#^/polarion/doorsconnector/rest#”> Require all denied
- If DOORS connector ends up used in the environment, limit access to the doorsconnector endpoint to only the specific IP address of the DOORS instance that Polarion synchronizes its data with.
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
For more information see the associated Siemens security advisory SSA-871717.