The remotely exploitable vulnerability, which ended up submitted to CISA anonymously, affects products that have uninstalled software using the Sentinel LDK Run-Time Environment, may have a port left open which may allow an attacker to connect.
Machines that previously ran and then uninstalled the following versions of Sentinel LDK Run Time Environment suffer from the issue: Versions 7.6 and prior.
This RTE is used in products by many different vendors. As new instances are discovered/reported, they will be added to this list of affected products.
In the vulnerability, the run-time environment installer adds a firewall rule named “Sentinel License Manager” that allows incoming connections from private networks using TCP Port 1947. While uninstalling, the uninstaller fails to close Port 1947.
CVE-2021-32928 is the case number for this vulnerability, which has a CVSS v3 base score of 9.6.
The product sees use in multiple industrial sectors, and on a global basis.
No known public exploits specifically target this vulnerability. However, an attacker with low skill level could leverage the low complexity vulnerability.
France-based Thales recommends vendors and users to upgrade to RTE Version 8.15 or later. https://cpl.thalesgroup.com/software-monetization/sentinel-drivers
If uninstalling with affected version, ensure “purge option” is selected. The purge option removes the Sentinel License Manager and closes the port.
If the affected product has been uninstalled:
- Ensure TCP Port 1947 is closed
- If possible, implement appropriate IDS/IPS measures against TCP Port 1947
For more information on products dependent on the affected RTE see the following vendor security advisories or updates:
Halliburton GOHFER: Update to Version 9.1.3.57 thru 9.2.x.xx and when uninstalling select the purge option. Upon uninstalling, the purge option removes the Sentinel License Manager and closes the port. Subsequent versions of GOHFER will no longer use Sentinel LDK.