There are no current mitigations developed for an exposure of sensitive information through sent data for a vulnerability in power line communications bus/PLC4TRUCKS/J2497 for multiple trailer and brake manufacturers, according to a report with CISA.
The National Motor Freight Traffic Association (NMFTA) and Assured Information Security (AIS) released research detailing a vulnerability within trailer Power Line Communications (PLC) signals. Their research indicates it is possible to read PLC signals using active antennas reliably at 6 feet and up to 8 feet away, subject to environmental conditions. The researchers expect to be able to push this reception distance further with receiver improvements.
The impact of this issue depends heavily on what information is being sent by ECUs on the trailer PLC bus. Typical trailer traffic is only ABS fault messages and will thus have minimal loss of confidentiality. CISA is publishing this advisory to bring awareness to trailer and brake manufacturers who may be seeking to leverage PLC for sensitive information: e.g., air weigh axles or key exchange in setting up high-speed wireless links in future tractor-trailer interfaces.
National Motor Freight Traffic Association (NMFTA) researcher Ben Gardiner, NMFTA motor freight carriers, and Assured Information Security researchers Dan Salloum, Chris Poore, and Eric Thayer discovered the vulnerability.
All trailer power line communications suffer from the issue.
In the vulnerability, PLC bus traffic can end up sniffed reliably via an active antenna up to 6 feet away. Further distances are also possible, subject to environmental conditions and receiver improvements.
CVE-2020-14514 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 4.3.
The product sees action mainly in the transportation systems sector, and on a global basis.
No known public exploits specifically target this vulnerability.
No current mitigations have been developed alongside this research. Future designs can mitigate this issue by reducing radiated emissions using shorter lengths of PLC buses and reduced transmit voltage.