Vistra filed the application with the Nuclear Regulatory Commission on Oct. 3, seeking to renew the licenses for an additional 20 years of operation. Comanche Peak’s two pressurized-water reactors, about 40 miles southwest of Fort Worth, Texas, are currently licensed to operate through Feb. 8, 2030, for Unit 1 and through Feb. 2, 2033, for Unit 2.
The NRC staff is reviewing the application to determine if it is sufficiently complete to begin the agency’s extensive safety and environmental reviews.
If the application is determined to be complete, the staff will docket it and publish a notice of opportunity to request an adjudicatory hearing before the NRC’s Atomic Safety and Licensing Board.
Comanche Peak is on the Squaw Creek Reservoir (SCR) in Somervell County, Texas about 4.5 miles north-northwest of Glen Rose, Texas, and 65 miles southwest of Dallas-Fort Worth in north-central Texas, according to the application.
The site area is7,700 acres, and the exclusion area is 4,170 acres. In addition to the two Comanche Peak reactors, the site includes the SCR and dam; the SCR, built for station cooling, extends northward into Hood County, according to the application. Each unit includes a four-loop, pressurized light-water reactor (LWR) Nuclear Steam Supply System (NSSS) supplied by Westinghouse Electric Corporation and associated equipment.
Commercial operation began for Comanche Peak Unit 1 on August 13, 1990 and began for Unit 2 on August 3, 1993. Each reactor was initially operated at a rated thermal power of 3411 Megawatt thermal (MWt), according to the application. In 1999, Unit 2 was uprated to 3445 MWt (an increase of 1 percent) through the use of use of leading edge flow-meter (LEFM) technology. In 2001, both units were uprated to 3458 MWt (1.4 percent for Unit 1 and an additional 0.4 percent for Unit 2) using LEFM technology.
In 2008, both units were uprated to 3612 MWt as a result of a Stretch Power Uprate (SPU), which was a 4.5 percent increase from the previous uprate, according to the application. The 2008 SPU implemented or took credit for several modifications: Setpoint changes for several systems and components, replacement of the Units 1 and 2 high-pressure turbines in order to pass the additional volumetric steam flow, replacement of the heater drain pump third-stage impellers and heater drain pump motors, re-rating of the main generators from 1350 to 1410 megavolt amperes, replacement of the hydrogen and exciter air coolers, replacement of the isophase bus duct coolers, replacement of the main transformers, and nine Unit 1 pipe support modifications.
Comanche Peak also operates an independent spent fuel storage installation (ISFSI) at the site.
The application is now available on the NRC website.