The purpose of this regulatory conference is for the Nuclear Regulatory Commission (NRC) and Entergy officials to discuss a preliminary finding of low-to-moderate safety significance before the agency makes a final determination.
The preliminary finding and a violation of NRC requirements involve radiation monitor calibration and maintenance issues affecting the plant, and the ability of operators to appropriately classify emergency action levels and perform radiation dose assessments. The finding was mentioned in an NRC June 11 inspection report.
NRC conducted an inspection conducted from April 24 to May 17 regarding the Waterford Steam Electric Station, Unit 3’s emergency preparedness programs.
NRC found a preliminary White finding with an associated apparent violation.
On January 18, licensee staff identified the engineering conversion and calibration factors used with the main condenser wide range gas monitor (WRGM) had been in error since January 1, 2011, according to the NRC report.
The condenser WRGM was used as part of the site’s emergency action level scheme until July 21, 2021, and is still used in radiological dose projection modeling for emergency response purposes. The errors resulted in the WRGM reading 69 to 76 percent higher than it should for the actual radiological conditions, which introduced the potential to overclassify radiological emergencies, and made the results of dose projections using the condenser WRGM inaccurate. These deficiencies were corrected on February 4.