Hydrogen gas is a promising energy source with several advantages as it is lightweight, storable, energy-dense, and environmentally friendly compared to fossil fuels. It also does not produce pollutants or greenhouse gas emissions.

As such, it has extensive applications across different fields, including transportation, architecture, power generation, and other industries. However, the downside is hydrogen is highly flammable, and therefore its safe and widespread use requires reliable methods for detecting leaks and ensuring its purity.

That is why the need for reliable detection methods has necessitated the development of trace-gas sensing techniques. And while there are several methods out there, so far none offer optimal performance.

One promising method, however, is tunable diode laser absorption spectroscopy (TDLAS) technology, which has gained significant attention for detecting various gases.

Key Advantages
TDLAS offers several key advantages, including non-contact measurement, in situ detection, high selectivity, rapid response, low cost, and multi-component, multi-parameter measurement capabilities.

Schneider Bold

It works on the principle that gases absorb light at a specific wavelength, resulting in a dark line in the absorption spectrum, known as the absorption line. By measuring the amount of laser light absorbed at this wavelength, it is possible to determine the concentration of the gas. However, detecting low concentrations of hydrogen with TDLAS is difficult because hydrogen has weaker absorption in the infrared region compared to other gases.

To address this issue, a research team from Japan led by Associate Professor Tatsuo Shiina from the Graduate School of Engineering, Chiba University, developed a method for precise hydrogen gas measurement using TDLAS. The team comprised Alifu Xiafukaiti and Nofel Lagrosas from the Graduate School of Engineering, Chiba University, Ippei Asahi from the Shikoku Research Institute Inc., and Shigeru Yamaguchi from the School of Science, Tokai University, worked on the project.

“In this study, we achieved highly sensitive detection of hydrogen gas through meticulous control of pressure and modulation parameters in the TDLAS setup. Additionally, we introduced a calibration-free technique that ensures the adaptability to a wide range of concentrations,” Shiina said.

Hydrogen detection

Chart shows the deviation of measured concentration (in parts per million) over varying integration times. 
Source: Tatsuo Shiina from Chiba University


Removing Environmental Noise
In TDLAS, laser light passes through a pressurized gas cell called a Herriott multipass cell (HMPC) containing the target gas. The laser’s wavelength ends up modulated or oscillated around the target absorption line of the gas at a specific frequency to remove any environmental noise. The pressure in HMPC can significantly influence the absorption line width and consequently the modulation parameters under TDLAS.

The researchers carefully analyzed the width of hydrogen’s strongest absorption line at different pressures. Through simulations, the researchers identified the optimal pressure for a broader absorption line width and the most effective modulation parameters within this line width.

Their calibration-free technique involved using the first harmonic of the modulated absorption signal to normalize the second harmonic through their ratio, instead of just relying on the second harmonic signal as in conventional TDLAS systems. Additionally, they employed a high-pressure gas cell containing pure hydrogen as a reference to fine-tune the modulating parameters of the laser signal.

Through this approach, the researchers achieved accurate measurements of hydrogen concentrations in a wide detection range from 0.01 percent to 100 percent, where 0.01 percent equals a concentration of just 100 parts per million (ppm). Moreover, the results improved with longer integration times (the time period during which light ends up allowed to absorb). At 0.1 second integration time, the minimum detection limit was 0.3 percent or 30,000 ppm, which improved to 0.0055 percent or 55 ppm at 30 seconds integration time. However, beyond 30 seconds the minimum detection limit increased.

“Our system can significantly improve hydrogen detection systems for safety and quality control, facilitating wider adoption of hydrogen fuel. For example, this system can be reliably used for the detection of leakages in hydrogen fuel cell cars,” Shiina said about potential applications.

Click here to view the entire paper.

Pin It on Pinterest

Share This