Six stands of 6 5/8-inch pipe fell from the finger row and landed on the starboard side deck of the derrick, according to an investigation by the Bureau of Safety and Environmental Enforcement (BSEE). Weather conditions at the time of the incident were 40 knot winds, heavy rain, and 8-10-foot seas. There were no personnel on the rig floor at the time of the incident.
The adverse weather conditions and the poor design of the casing fingerboard system were the main causes of the incident, BSEE investigators found.
With new locking bolt arrangements with improved functionality, operators can adjust the width of the row by flip-over beams that consist of a hinged square hollow steel profile, or a steel plate. The adjustments can occur remotely or manually.
In October 2023, a manufacturer product improvement notification ended up issued to inform offshore personnel about the availability of new locking bolt arrangements with improved functionality.
The previous locking bolt design underwent a redesign and enhancement to ensure improved and effective bolt locking. The enhanced locking bolt arrangement consists of a bolt, locking clip, and safety pin, which, when installed, prevents the bolt from unscrewing.
- To that end, the BSEE recommends operators and their contractors consider the following:
- Inspect the condition of all casing fingerboard beam locking bolts.
- Review fingerboard design and ensuring the best available locking mechanism ends up implemented. Contact vendor and/or manufacturer to confirm.
- Inspect and check the pressure applied by air cylinders to ensure proper application of pressure to the flip over beam.
- Ensure all racked casing and pipe undergo proper and secure storage and cannot fall out of the fingerboard during adverse weather.
- Subscribing to and reviewing all original equipment manufacturer product bulletins and alerts.
- Adhering to Red Zone Management when required.
- Review the following BSEE publications related to pipe handling and racking systems for additional information and recommendations:
— Safety Alert 324: Regarding four pipe racking system incidents
— Safety Bulletin 2 and Panel Report 2017-001: Regarding a fatality following a fingerboard latch malfunction during pipe handling